sint
sint2
sint3

S201 DustGuard, S203 Trend Monitor

• Good value for money
• Easy start-up and commissioning
• Rugged design for harsh industrial
conditions
• Proven technology
• Accurate dust measurement
• Extremely wide measurement range
• Normalized (instruments are all
identical) instrument with a
detection limit of 0,01mg/m3

Common Filtration Control

• Straightforward filter leak detection on an ALERT
and ALARM signal base
• Filter performance monitoring and optimization
on the mA output signal of S203
• Minimize product loss by finding even the
smallest leakages
• Identify broken solenoid valves
• Monitor pulse efficiency and reduce pulse rates
• Reduce consumption of compressed air
• Enable preventive maintenance
• Proactively reduce emergency downtime

Product Name S201, S203
Measurement objects Total Suspended Particles (TSP)
Measurement range Detection Limit 0,01 mg/m³

Maximum Range up to several g/m³, depending on conditions

Measurement principle Inductive Electrification
Protection code IP65
Power supply 24 VDC and 80-240 VAC
Power consumption Up to 10 W
Output signals •      Two dry contact Relays, max 5A@30VDC / 5A@240VAC

•      Isolated 4-20 mA output loop (S203)

Communication interface •      Serial communication RS-485

•      USB

Communication protocol •      Modbus RTU (RS-485)

•      Sintrol network (USB, RF and RS-485)

Ambient Conditions
Temperature -40°C to +60 °C (-40 °F to 140 °F)
Humidity Max 95 % RH (non-condensing)
Materials and Weight
Enclosure / casing Aluminum
Weight 1,5 kg (3,3 lbs)
Process conditions
Temperature Max 200 °C (392 °F) default, optionally up to 700 °C (1292 °F)
Pressure Max 300 kPa default, optionally up to 6000 kPa
s303
sint2

S303 & S304 DUST MONITORS

Product Name S303, S304
Measurement objects Total Suspended Particles (TSP)
Measurement range Detection Limit 0,01 mg/m³

Maximum Range up to several g/m³, depending on conditions

Measurement principle Inductive Electrification
Protection code IP65
Power supply 24 VDC and 80-240 VAC
Power consumption Up to 10 W
Output signals •      Two dry contact Relays, max 5A@30VDC / 5A@240VAC

•      Isolated 4-20 mA output loop

Communication interface •      2 x Serial communication RS-485

•      USB

•      Radio frequency (RF) (only on RF models)

Communication protocol •      Modbus RTU (RS-485)

•      Sintrol network (USB, RF and RS-485)

Ambient Conditions
Temperature -40°C to +60 °C (-40 °F to 140 °F)
Materials and Weight
Enclosure / casing Aluminum
Weight 1,5 kg (3,3 lbs)
Process conditions
Temperature Max 200 °C (392 °F) default, optionally up to 700 °C (1292 °F)
Pressure Max 300 kPa default, optionally up to 6000 kPa
Humidity Max 95% RH (non-condensing)
Wireless Communication (only for RF models)
Frequency band 868 MHz or 915 MHz, 15 channels
Transmitting power Up to +23 dBm, user adjustable
Receiver sensitivity -110 dBm
Communication protocol Proprietary Sintrol Network protocol
Typical range •      868 MHz Version

•      Up to 1000 m (3280 ft) in urban environment

•      NOTE: The RF communication range is highly affected by the surrounding  structures and other RF devices.